In the field of extra-large DC current power supply, multiple rectifier units are usually used to operate in parallel. During normal operation, the current of each unit is respectively fed into the general converging bus. When one of the rectifier units in working state has short circuit and other faults, the system current will flow to the faulty unit, thus forming reverse current, causing major production accidents such as unit damage or series unit damage.
Email:
Product Details
1. Overview
In the field of extra-large DC current power supply, multiple rectifier units are usually used to operate in parallel. During normal operation, the current of each unit is respectively fed into the general converging bus. When one of the rectifier units in working state has short circuit and other faults, the system current will flow to the faulty unit, thus forming reverse current, causing major production accidents such as unit damage or series unit damage.
The device has the characteristics of reliable performance, fast reflection speed, convenient installation and maintenance, and can be widely used in non-ferrous, chemical, power transmission and other industries of DC continuous measurement, measurement and control.
In the DC application field, multiple rectifier units are usually operated in parallel. When the rectifier units work normally, the current of the sub-units flows into the total bus in the direction of the solid line. When one of the rectifier units in the working state has a short-circuit fault, the system current will flow to the faulty rectifier cabinet (I .e. the total bus current flows in the direction of the dotted line), thus forming reverse current, resulting in damage to the single rectifier cabinet or avalanche of the entire unit. The SDA-N countercurrent measurement and control system is installed. When the rectifier unit works normally, the measurement and control system can realize the current measurement function. Once the rectifier unit fails to produce countercurrent, the measurement and control system will detect the size of countercurrent in time, and provide signals for the overcurrent (pressure) protection system through the countercurrent detector, cut off the network side, control the protection trip circuit, and prevent major accidents.
The KDA-N countercurrent measurement and control system has the characteristics of reliable performance, fast response speed, convenient installation and maintenance, and can be used in non-ferrous, chemical, power transmission and other industries of DC continuous measurement, measurement and control.
Main technical parameters of 2.
Response time: ≤ 50nS
Range: 6KA, 10KA, 15KA, 20KA, 25KA, 35KA, 50KA, 65KA, 75KA
Accuracy: 0.5%(reading x 0.5%+ full scale value x 0.2%)-L
Other factors affecting the magnitude error (accuracy 0.1%):
1. When the eccentric size of the position influence sensor is the 1/3 of the distance from the busbar to the window edge, the additional position error is not more than 0.05
The repeated loading and unloading error is less than 0.05%.
2. Stray field influence When the field stray magnetic field is not more than 200GS, the influence of stray magnetic field on the accuracy of the sensor is not more than 0.05
The additional temperature error is 0~45 ℃, and the additional temperature error of the sensor is not more than 0.05% per 10 ℃ on average.
Power consumption: <5W
Insulation resistance: in the environment of 15~35 ℃, relative humidity of 45~75 ℃, the insulation resistance between the sensor power terminal to the shell is greater than 20MΩ
Overload capacity: infinite (after overrange, the accuracy is not guaranteed, but the sensor will not be damaged)